Unverified paper record
A Novel Approach for Monitoring The Spatial Distribution and Quantitative Analysis of Micronutrients in Plant Tissues Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry Imaging
American Chemical Society (ACS) · 8 Jul 2026 · 10.26434/chemrxiv.15005803/v1
Abstract
Quantitative imaging of plant tissues by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is hindered by the lack of matrix-matched calibration standards. Established approaches, such as gelatine or homogenized tissue blocks, do not replicate plant matrices accurately. Here, we introduce a nano-dispenser-based calibration strategy that deposits nanolitre volumes of elemental standards directly onto paraffin-embedded grain sections, exploiting the low endogenous metal content of the endosperm to generate in situ calibration curves. Calibration performance for Mg, Mn, Cu, Zn and Mo was assessed using LA-ICP-MS imaging and Iolite data processing. The method demonstrated excellent linearity (R2 > 0.98), reproducibility across multiple grains, and sub-ppm limits of detection. Comparative analysis with in-house homogenized blocks and NIST wheat reference material confirmed superior accuracy and reproducibility of the nano-dispenser approach. As a proof-of-concept we have applied the method for the quantitative imaging of metals in a whole barley grain section and the results show excellent agreement with published data obtained by conventional liquid-mode ICP MS. The technique reported here provides a robust, scalable solution for quantitative metallomics studies of plants tissues, enabling improved assessment of nutrient distribution and supporting the development of standardised protocols for LA-ICP-MS Imaging
Plant phenotyping relevance
植物組織中の元素分布を定量画像化するための校正手法を開発し、直線性・再現性・精度を検証している。栄養元素という植物形質の取得法が研究の中心である。
abstractHere, we introduce a nano-dispenser-based calibration strategy that deposits nanolitre volumes of elemental standards directly onto paraffin-embedded grain sections
abstractCalibration performance for Mg, Mn, Cu, Zn and Mo was assessed using LA-ICP-MS imaging and Iolite data processing.
abstractComparative analysis with in-house homogenized blocks and NIST wheat reference material confirmed superior accuracy and reproducibility of the nano-dispenser approach.
Code and data availability
公開論文であることは確認できましたが、現在の公式API・許可済み取得経路では本文を自動取得できませんでした。
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.