Unverified paper record
The use of a portable X-ray fluorescence spectrometer for measuring nickel in plants: sample preparation and validation.
Environmental monitoring and assessment · 11 May 2024 · 10.1007/s10661-024-12706-y
Abstract
X-ray fluorescence is a fast, cost-effective, and eco-friendly method for elemental analyses. Portable X-ray fluorescence spectrometers (pXRF) have proven instrumental in detecting metals across diverse matrices, including plants. However, sample preparation and measurement procedures need to be standardized for each instrument. This study examined sample preparation methods and predictive capabilities for nickel (Ni) concentrations in various plants using pXRF, employing empirical calibration based on inductively coupled plasma optical emission spectroscopy (ICP-OES) Ni data. The evaluation involved 300 plant samples of 14 species with variable of Ni accumulation. Various dwell times (30, 60, 90, 120, 300 s) and sample masses (0.5, 1.0, 1.5, 2.0 g) were tested. Calibration models were developed through empirical and correction factor approaches. The results showed that the use of 1.0 g of sample (0.14 g cm -2 ) and a dwell time of 60 s for the study conditions were appropriate for detection by pXRF. Ni concentrations determined by ICP-OES were highly correlated (R 2 = 0.94) with those measured by the pXRF instrument. Therefore, pXRF can provide reliable detection of Ni in plant samples, avoiding the digestion of samples and reducing the decision-making time in environmental management.
Plant phenotyping relevance
植物試料中のNi濃度を測定するpXRF手法について、試料調製・測定条件・校正・ICP-OESとの比較検証を中心に扱っており、植物の元素状態を取得する測定法の技術的妥当性評価である。
abstractThis study examined sample preparation methods and predictive capabilities for nickel (Ni) concentrations in various plants using pXRF
abstractCalibration models were developed through empirical and correction factor approaches.
abstractNi concentrations determined by ICP-OES were highly correlated (R 2 = 0.94) with those measured by the pXRF instrument.
Code and data availability
The paper reports pXRF/ICP-OES Ni measurements on 300 plant samples, but states 'Data availability Not applicable.' No public phenotype dataset, code, model, or supplementary asset with an authors' URL is described; the supplementary information link is only mentioned without content details.
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.