Unverified paper record
3D Visualization of Bamboo Node’s Vascular Bundle
Forests · 17 Dec 2021 · 10.3390/f12121799
Abstract
The vascular bundle is an important structural unit that determines the growth and properties of bamboo. A high-resolution X-ray microtomography (μCT) was used to observe and reconstruct a three-dimensional (3D) morphometry model of the vascular bundle of the Qiongzhuea tumidinoda node due to its advantages of quick, nondestructive, and accurate testing of plant internal structure. The results showed that the morphology of vascular bundles varied significantly in the axial direction. In the cross-section, the number of axial vascular bundles reached a maximum at the lower end of the sheath scar, and the minimum of it was at the middle of the diaphragm. The frequency of axial vascular bundles decreased from the lower end of the node to the nodal ridge, and subsequently increased until the upper end of the bamboo node. The proportion of parenchyma, fibers, and conducting tissue was 65.7%, 30.5%, and 3.8%, respectively. The conducting tissues were intertwined to form a complex 3D network structure, with a connectivity of 94.77%. The conducting tissue with the largest volume accounted for 60.26% of the total volume of the conducting tissue. The 3D-distribution pattern of the conducting tissue of the node and that of the fibers were similar, but their thickness changed in the opposite pattern. This study revealed the 3D morphometry of the conducting tissue and fibers of the bamboo node, the reconstruction of the skeleton made the morphology more intuitive. Quantitative indicators such as the 3D volume, proportion, and connectivity of each type of tissue was obtained, the bamboo node was enlarged mainly caused by the particularly developed fibers. This work laid the foundation for a better understanding of the mechanical properties and water transportation of bamboo and revealed the mystery of bamboo node shedding of Q. tumidinoda.
Plant phenotyping relevance
植物ノード内部の維管束・繊維の3D形態をμCTで取得・再構築し、体積・割合・接続性などの定量形質を抽出することが研究の中心であり、単なる routine measurement ではない。
abstractA high-resolution X-ray microtomography (μCT) was used to observe and reconstruct a three-dimensional (3D) morphometry model of the vascular bundle
abstractQuantitative indicators such as the 3D volume, proportion, and connectivity of each type of tissue was obtained
Code and data availability
The paper describes μCT scanning of a Qiongzhuea tumidinoda bamboo node with image processing in Fiji/ImageJ, NRecon, and AVIZO, but provides no public dataset, image stack, code, or model deposit. The Data Availability Statement reads 'Data Availability Statement: Not applicable.' Fiji is a generic open-source library
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.