Unverified paper record
Optimization of LF-NMR-based methods for analysis of oil content and distribution in germinating oilseeds.
Journal of the science of food and agriculture · 27 Mar 2026 · 10.1002/jsfa.70591
Abstract
Background Lipid metabolism is critical for seed germination, directly impacting their nutritional value as a food raw material. Conventional methods for oil analysis are destructive and fail to determine oil distribution. This study evaluated the feasibility of using low-field nuclear magnetic resonance (LF-NMR) coupled with magnetic resonance imaging (MRI) as a non-destructive approach for monitoring oil changes in germinating oilseeds. Results Four representative oilseed varieties - herbaceous (peanut, soybean) and woody (camellia, almond) - were investigated to analyze oil changes during germination. The accuracy of LF-NMR was validated against Soxhlet extraction and confocal laser scanning microscopy (CLSM). The results revealed that herbaceous seeds exhibited rapid oil mobilization germination, whereas woody seeds showed slower oil consumption. High correlations were observed between LF-NMR method and conventional method/CLSM imaging method (R 2 > 0.9). Notably, MRI-imaging oil ratio demonstrated the highest accuracy in quantifying both oil content and distribution. Greenness evaluation results show that LF-NMR is the greenest method for sample preparation and measurement process. Conclusion These findings confirm LF-NMR as an effective method for non-destructive monitoring of oil content and distribution during seed germination, which holds significant application potential in areas such as food raw material quality assessment and the optimization of oilseed processing pretreatment. © 2026 Society of Chemical Industry.
Plant phenotyping relevance
発芽油種子の油含量・分布という植物器官の状態を、LF-NMR/MRIで非破壊測定する手法を開発・検証しており、表現型取得法が研究の中心である。
abstractThis study evaluated the feasibility of using low-field nuclear magnetic resonance (LF-NMR) coupled with magnetic resonance imaging (MRI) as a non-destructive approach for monitoring oil changes in germinating oilseeds.
abstractThe accuracy of LF-NMR was validated against Soxhlet extraction and confocal laser scanning microscopy (CLSM).
abstractThese findings confirm LF-NMR as an effective method for non-destructive monitoring of oil content and distribution during seed germination
Code and data availability
公開本文の所在を確認できませんでした。非公開または購読が必要な可能性があります。
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.