Low-Cost Custom-Built Flow Meters for Plant Hydraulic Conductance: Validation of Accuracy, Precision, and Reproducibility.
Plant direct · 23 Feb 2026 · 10.1002/pld3.70154
Abstract
Measurement of xylem hydraulic conductance provides access to xylem hydraulic conductivity and vulnerability to cavitation, two key traits for assessing plant sensitivity to environmental stressors. We evaluated the performance of custom-built low-cost pressure drop flow meters through nearly 1200 measurements across devices, laboratories, reservoir heights (10, 25 and 45 cm, used to induce pressure head and drive water flux) and PEEK tubing of hydraulic contrasting resistances. Flow meters were interchangeable, with mean differences generally < 3.5% and never exceeding 5%, with 88.9% of comparative tests showing no significant difference. Under recommended conditions (25-45 cm pressure head, downstream-to-upstream pressure ratio ≈0.5), precision reached 1%-7% coefficient of variation. Accuracy, assessed against reference values obtained by water displacement, was also strong, with 68% of measurements deviating by < 5% from reference values and over 78% when measured at {greater than or equal to}25 cm. At 10 cm, performance declined because sensor deviations represented a larger fraction of pressure differential, and low-resistance PEEK tubing increased absolute but not relative error. Validated flow meters proved portable, affordable (≈2500 CAD), and reliable. Their low cost, open-source interface, and publicly available construction protocol make them accessible to laboratories with limited resources, enabling reproducible multi-laboratory studies of plant hydraulics and fostering international collaborations.
Plant phenotyping relevance
植物の木部油圧コンダクタンスという生理形質を測定する低コスト流量計を開発・検証し、精度・再現性・多施設間性能を評価しているため、植物フェノタイピング手法が研究の中心である。
abstractWe evaluated the performance of custom-built low-cost pressure drop flow meters through nearly 1200 measurements across devices, laboratories, reservoir heights (10, 25 and 45 cm, used to induce pressure head and drive water flux) and PEEK tubing of hydraulic contrasting resistances.
abstractAccuracy, assessed against reference values obtained by water displacement, was also strong
abstractValidated flow meters proved portable, affordable (≈2500 CAD), and reliable.
Code and data availability
The paper describes paper-specific assets: a hydraulic conductance measurement dataset deposited on FRDR (DOI 10.20383/103.01429) and the authors' R Shiny analysis application code (UrliLab/Flowmeter-Project, Zenodo DOI 10.5281/zenodo.16969363, 'available on GitHub'). However, neither the FRDR nor GitHub/Zenodo URLs is