Unverified paper record
Micro-CT Imaging of Low-density Plant Stems
Springer Science and Business Media LLC · 17 Jan 2022 · 10.21203/rs.3.rs-1251568/v1
Abstract
Abstract Background Micro-CT (X-ray computed tomographic) allows for 3D visualization of an entire structure, both internally and externally. The different materials are identified based on the differences in their ability to attenuate X-ray, with the differences being converted into a range of grey values. Low-density plant tissues with limited differences in grey values create a challenge in differentiating the cellular structures. In addition, internal movements due to autolysis, degradation, and shrinkage during dehydration of the tissues during scanning give rise to blurry images. Results In this study, oats and wheat were scanned using micro-CT to optimize the use of micro-CT in low-density plants. With the assistance of chemical fixing, phosphotunstate and a chemical drying agent, we were able to visualize microstructures of cereal stems. These preparation steps allow us to create 3D micrographs of low-density stem nodes suggesting key structural differences that are correlated with lodging resistance. Conclusion Micro-CT is a valuable tool to create 3D structural images of low-density material. Multiple steps to prepare the samples to stop autolysis, increase the contrast during scanning and eliminate internal movement are described in this paper. This process allowed for visualization of the stem nodal region suggesting morphology related to lodging resistance.
Plant phenotyping relevance
低密度植物茎の内部構造を取得するため、マイクロCT撮像と試料調製を最適化・開発しており、植物形態の3D表現型取得が中心です。
abstractIn this study, oats and wheat were scanned using micro-CT to optimize the use of micro-CT in low-density plants.
abstractMultiple steps to prepare the samples to stop autolysis, increase the contrast during scanning and eliminate internal movement are described in this paper.
abstractThis process allowed for visualization of the stem nodal region suggesting morphology related to lodging resistance.
Code and data availability
The preprint describes micro-CT imaging of oat and wheat stems with structural trait measurements, but no public dataset, image, or code deposit is provided. The authors state the datasets are available only on reasonable request; the supplementary file is a figure describing measurements, not a data/code asset.
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.