Unverified paper record
Effects of moisture content on in situ analysis of plant samples using portable XRF.
Environmental pollution (Barking, Essex : 1987) · 26 May 2026 · 10.1016/j.envpol.2026.128414
Abstract
Analysis of the element composition of plant materials has many applications, including monitoring nutrient status, detecting biogeochemical indications of mineral deposits and assessing the effectiveness of phytoremediation in contaminated soils. Portable X-ray fluorescence spectroscopy (pXRF) delivers the advantage of real time in situ multi-elemental analysis at low cost, but calibration is affected by factors that include the water content of plant organs. The effect of variation in moisture content on pXRF-determined concentrations of heavy metals Zn, Fe, Cu, Sr and Th, and nutrient elements Si, S, K and Ca, have been evaluated using the foliage of A. imperialis, D. excelsa and A. macrorhiza through a controlled continuous drying experiments. A segmented linear relationship between pXRF measurements and moisture content was observed for most elements with a rapid decrease followed by a moderate decrease as moisture content increased. The position of the inflection point is dependent on leaf thickness and energy of the main X-ray peak measured. Calibration issues related to variation in moisture content comprises a combination of dilution and spectral interference effects. Dilution accounts for most of the underestimation of pXRF-determined concentrations for fresh plant samples compared with laboratory methods on dried samples. As moisture contents increase, the relative influence of spectral interferences decreases. The single-layer thickness of plant sample affects the position of inflection point of linearity and the relative contribution of spectral interference effect. This study provides new insights into the effect of moisture on pXRF-determined elemental concentrations and offers practical suggestions and recommendations for in situ analysis of plant samples using pXRF.
Plant phenotyping relevance
植物試料の元素濃度を測定するpXRFについて、水分含量による測定誤差と校正特性を評価し、実 in situ 測定への実用的推奨を示す方法検証研究である。
abstractcalibration is affected by factors that include the water content of plant organs
abstractThe effect of variation in moisture content on pXRF-determined concentrations of heavy metals Zn, Fe, Cu, Sr and Th, and nutrient elements Si, S, K and Ca, have been evaluated
abstractThis study provides new insights into the effect of moisture on pXRF-determined elemental concentrations and offers practical suggestions and recommendations for in situ analysis of plant samples using pXRF.
Code and data availability
公開論文であることは確認できましたが、現在の公式API・許可済み取得経路では本文を自動取得できませんでした。
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.