← Papers

Unverified paper record

Using continuous soil and plant water status sensors calibrated against stem water potential for irrigation scheduling – nectarine as a test case

Springer Science and Business Media LLC · 23 May 2024 · 10.21203/rs.3.rs-4399393/v1

Abstract

Abstract This study investigated the use of on-site calibrated soil and plant based sensors for irrigation control in a nectarine (Prunus persica) , orchard on heavy clay soil. Irrigation was applied according to predetermined mid-day stem water potential (SWP) thresholds for each of the three phenological stages of fruit development. Calibration of sensors relative to SWP was done in a drying and wetting plot in a separate part of the orchard. Irrigation was withheld in that plot for several periods of time during two seasons, allowing SWP of six nectarine trees to reach values of moderate water stress. The readings of continuous tensiometers, soil volumetric water content sensors and dendrometers were regressed on those of SWP at that time. Water stress thresholds were then calculated from the regressions and subsequently used for irrigation scheduling. The irrigation aimed to keep non-limiting conditions in stages Ⅰ and Ⅲ by keeping SWP at ~-0.9 MPa, and moderate water stress in stage Ⅱ by keeping SWP at ~-1.5 MPa. Adjustments were made weekly in five treatment plots for each sensor type, according to the thresholds. Results showed that tensiometers could be used for stages Ⅰ and Ⅲ, as they were highly sensitive to small changes in soil wetness. However, when stress was applied soil water tension exceeded the range of the tensiometer sensors at 30 cm depth.

Plant phenotyping relevance

植物・土壌水分センサーを茎水ポテンシャルに対して校正し、連続的な植物水分状態の測定性能と閾値利用を評価しており、単なる灌漑試験ではなくセンサーによる生理形質取得が中心です。

titleUsing continuous soil and plant water status sensors calibrated against stem water potential for irrigation scheduling – nectarine as a test case
abstractCalibration of sensors relative to SWP was done in a drying and wetting plot in a separate part of the orchard.
abstractThe readings of continuous tensiometers, soil volumetric water content sensors and dendrometers were regressed on those of SWP at that time.
abstractResults showed that tensiometers could be used for stages Ⅰ and Ⅲ, as they were highly sensitive to small changes in soil wetness.

Code and data availability

The supplied article blocks contain no data availability statement, no public dataset deposit, no author code/scripts, and no supplementary files with sensor measurements or analysis workflows. All URLs in the text are citations to prior work or the paper's own DOI/Version of Record, none of which qualify as paper-phen

No evidence-backed public reproduction asset is currently recorded.

This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.