Unverified paper record
RotatedStomataNet: a deep rotated object detection network for directional stomata phenotype analysis.
Plant cell reports · 23 Apr 2024 · 10.1007/s00299-024-03149-3
Abstract
Key message Innovatively, we consider stomatal detection as rotated object detection and provide an end-to-end, batch, rotated, real-time stomatal density and aperture size intelligent detection and identification system, RotatedeStomataNet. Stomata acts as a pathway for air and water vapor in the course of respiration, transpiration, and other gas metabolism, so the stomata phenotype is important for plant growth and development. Intelligent detection of high-throughput stoma is a key issue. Nevertheless, currently available methods usually suffer from detection errors or cumbersome operations when facing densely and unevenly arranged stomata. The proposed RotatedStomataNet innovatively regards stomata detection as rotated object detection, enabling an end-to-end, real-time, and intelligent phenotype analysis of stomata and apertures. The system is constructed based on the Arabidopsis and maize stomatal data sets acquired destructively, and the maize stomatal data set acquired in a non-destructive way, enabling the one-stop automatic collection of phenotypic, such as the location, density, length, and width of stomata and apertures without step-by-step operations. The accuracy of this system to acquire stomata and apertures has been well demonstrated in monocotyledon and dicotyledon, such as Arabidopsis, soybean, wheat, and maize. The experimental results that the prediction results of the method are consistent with those of manual labeling. The test sets, the system code, and their usage are also given ( https://github.com/AITAhenu/RotatedStomataNet ).
Plant phenotyping relevance
気孔の位置・密度・開口部サイズなどの植物表現型を自動取得する深層学習システムを開発し、複数作物で精度検証しているため、植物フェノタイピング手法が中心である。
abstractprovide an end-to-end, batch, rotated, real-time stomatal density and aperture size intelligent detection and identification system
abstractenabling the one-stop automatic collection of phenotypic, such as the location, density, length, and width of stomata and apertures
abstractThe experimental results that the prediction results of the method are consistent with those of manual labeling.
Code and data availability
公開本文の所在を確認できませんでした。非公開または購読が必要な可能性があります。
No evidence-backed public reproduction asset is currently recorded.
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.