← Papers

Unverified paper record

Direct determination of nutrient elements in plant leaves by double pulse laser-induced breakdown spectroscopy: evaluation of calibration strategies using direct and inverse models for matrix-matching.

Analytical methods : advancing methods and applications · 24 Mar 2022 · 10.1039/d1ay02101j

Abstract

This study aims to develop a single calibration model to determine nutrient elements directly (Ca, Mg, Mn, and P) in soybean and sugar cane leaf samples by double pulse laser-induced breakdown spectroscopy (DP LIBS). Matrix-matching calibration (MMC) was evaluated using direct and inverse models. Forty-five samples were used to build the calibration model (23 soybean leaves and 22 sugar cane leaves), and fifteen were used for the prediction test (8 soybean leaves and 7 sugar cane leaves) models. In the direct model, the analyte concentration in the sample is the independent variable, and the analytical signal is the dependent variable. In the inverse model, the analytical signal is the independent variable, and the analyte concentration in the sample is the dependent variable. In general, both models presented satisfactory results; however, the inverse model performed better. Emission lines used to propose calibration models were selected using a linear Pearson's correlation ( R ) strategy between each spectral point and the Ca, Mg, Mn, and P concentration measured by reference methods using inductively coupled plasma optical emission spectrometry (ICP OES). The root mean square errors of prediction (RMSEP) for the direct models were 0.60 g kg -1 to (Ca), 0.47 g kg -1 (Mg), 9.3 mg kg -1 to (Mn), and 0.28 g kg -1 to (P); for inverse model was 0.55 g kg -1 to (Ca), 0.39 g kg-1 (Mg), 10.5 mg kg -1 to (Mn), and 0.21 g kg -1 to (P). The calibration strategies proposed in this study may minimize matrix effects in direct solid analysis in soybean and sugar cane leaf samples, performing the determination of Ca, Mg, Mn, and P by DP LIBS using a single calibration model.

Plant phenotyping relevance

植物葉中の栄養元素濃度という生理状態を、DP LIBSで直接定量する校正法を開発・評価しており、取得・抽出手法が研究の中心である。

abstractThis study aims to develop a single calibration model to determine nutrient elements directly (Ca, Mg, Mn, and P) in soybean and sugar cane leaf samples by double pulse laser-induced breakdown spectroscopy (DP LIBS).
abstractMatrix-matching calibration (MMC) was evaluated using direct and inverse models.
abstractThe calibration strategies proposed in this study may minimize matrix effects in direct solid analysis in soybean and sugar cane leaf samples

Code and data availability

公開本文の所在を確認できませんでした。非公開または購読が必要な可能性があります。

No evidence-backed public reproduction asset is currently recorded.

This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.