Supplementary Table S1: SNR of hyperspectral images acquired under different illumination sources in two cut rose cultivars (‘All For Love’ and ‘White Beauty’); Figure S1: Effect of light sources on hyperspectral image (HSi) quality in cut roses ‘All For Love’ and ‘White Beauty’.
Open resource ↗lines:64-174Unverified paper record
Light Sources in Hyperspectral Imaging Simultaneously Influence Object Detection Performance and Vase Life of Cut Roses.
Plants (Basel, Switzerland) · 9 Jan 2026 · 10.3390/plants15020215
Abstract
Hyperspectral imaging (HSI) is a noncontact camera-based technique that enables deep learning models to learn various plant conditions by detecting light reflectance under illumination. In this study, we investigated the effects of four light sources-halogen (HAL), incandescent (INC), fluorescent (FLU), and light-emitting diodes (LED)-on the quality of spectral images and the vase life (VL) of cut roses, which are vulnerable to abiotic stresses. Cut roses 'All For Love' and 'White Beauty' were used to compare cultivar-specific visible reflectance characteristics associated with contrasting petal pigmentation. HSI was performed at four time points, yielding 640 images per light source from 40 cut roses. The results revealed that the light source strongly affected both the image quality (mAP@0.5 60-80%) and VL (0-3 d) of cut roses. The HAL lamp produced high-quality spectral images across wavelengths (WL) ranging from 480 to 900 nm and yielded the highest object detection performance (ODP), reaching mAP@0.5 of 85% in 'All For Love' and 83% in 'White Beauty' with the YOLOv11x models. However, it increased petal temperature by 2.7-3 °C, thereby stimulating leaf transpiration and consequently shortening the VL of the flowers by 1-2.5 d. In contrast, INC produced unclear images with low spectral signals throughout the WL and consequently resulted in lower ODP, with mAP@0.5 of 74% and 69% in 'All For Love' and 'White Beauty', respectively. The INC only slightly increased petal temperature (1.2-1.3 °C) and shortened the VL by 1 d in the both cultivars. Although FLU and LED had only minor effects on petal temperature and VL, these illuminations generated transient spectral peaks in the WL range of 480-620 nm, resulting in decreased ODP (mAP@0.5 60-75%). Our results revealed that HAL provided reliable, high-quality spectral image data and high object detection accuracy, but simultaneously had negative effects on flower quality. Our findings suggest an alternative two-phase approach for illumination applications that uses HAL during the initial exploration of spectra corresponding to specific symptoms of interest, followed by LED for routine plant monitoring. Optimizing illumination in HSI will improve the accuracy of deep learning-based prediction and thereby contribute to the development of an automated quality sorting system that is urgently required in the cut flower industry.
Plant phenotyping relevance
切り花の状態評価に用いるHSIについて、照明条件が画像品質と検出精度に及ぼす影響を比較・検証し、実運用向けの照明戦略を提案しているため、植物フェノタイピング手法が中心である。
abstractwe investigated the effects of four light sources-halogen (HAL), incandescent (INC), fluorescent (FLU), and light-emitting diodes (LED)-on the quality of spectral images and the vase life (VL) of cut roses
abstractOur results revealed that HAL provided reliable, high-quality spectral image data and high object detection accuracy
abstractOur findings suggest an alternative two-phase approach for illumination applications that uses HAL during the initial exploration of spectra corresponding to specific symptoms of interest, followed by LED for routine plant monitoring.
Code and data availability
保存済みの本文根拠を更新済みルールで再検証し、公開資産1件を確認しました。
This is an automatically classified, unverified record. Curator approval is required before any resource enters the Catalog.